general data repeat accuracy < 0,001 mm activating force 75 cn mech. pre-run / overrun - / 0,8 ... 1,5 mm approx. measurement type contact with medium direction of approach frontal and lateral approach output indicator led red electrical data voltage supply range +vs 5 ... 36 vdc load current max. at 24 vdc 50 ma load resistance min. 480 ohm output circuit pnp make function (no) mechanical data activating pin hardened steel housing material brass nickel plated dimension 6 mm type cylindrical threaded housing length 47 mm connection types cable, 80 cm ambient conditions operating temperature -20 ... +75 c protection class ip 50 photo connection diagram output +v s pnp bu (3) bn (1) bk (4) z 0 v dimension drawing 1, 2 m6 x 0, 5 2, 5 ? 15 47 10 ? sw 8 le d 19/1/2015 my-com e75p80/l my-com e75p80/l my-com precision switches my-com precision switches www.baumer.com
|